Pump Controllers
3P Technik UK‘s wide range of rainwater harvesting, mains top-up, level control and pump controllers are under constant development by our innovative engineers. The controllers can operate any type of pump or fluid. There are complex multi-pump and/or multi-tank Controllers, through to basic timer Controllers. They are ideal deployed with above ground tanks, or where one tank needs to feed another tank, or to balance tank levels.
if you need more information, help selecting the best pump control panel for your needs or simply want to buy our products, please Contact Us or call us on 01239 623506.
Single Pump Controller with CosPhi Dry Run Protection – Quadri CosPhi
1 or 2 Pump Controller – Direct On-line Starter – Quadri
PC3S Metal Direct On-Line Pump Controller 400VAC
PC3S Compact Direct On-Line Pump Controller 400VAC
Single/Twin Tank Level Controller
Voltage Control – 3F Control
DIN Rail Mounted Level Controller – Sensopress
DIN Rail Mounted Pump Sequencer 3
DIN Rail Mounted Pump Sequencer 2q
DIN Rail Mounted Pump Sequencer 2
DIN Rail Mounted Pump Sequencer
Pump Inverter – Swimming Pool Pumps – HydroController Pool
Pump Inverter – Off-Grid Solar Installations – HydroController Solar
Programmable Pump Inverters – HydroController
Compact Water-cooled Inverter – E-Power
Compact Air-Cooled Inverter – E-Power All in One
Adjustable Pressure Switch – Mechanical – MacPress
Pump Pressure Switch – Adjustable Pressure – PresSystem
Home Boosting – Electronic Pump Pressure Controller – E-Control
Home Boosting – Electronic Flow Switch – E-Flow
Electronic Pump Controller – SuperSimplex E
Electromechanical Pump Controller – SuperSimplex M
Inverter with External Sensors: Single / Three Phase 230V and 400V
Self Contained, Pump Outlet Mounted Inverter: Single / Three Phase 230V
Multiple Booster Pump Controller
Single Pump Controller with CosPhi Dry Run Protection – Quadri CosPhi
Quadri CosPhi Pump Control/Protection Panel of a single submersible pump. Built in Dry Run Protection using CosPhi monitoring of the motor itself .
Options for Single Phase or Three Phase. This Controller can function in either an automatic or manual configuration.1 or 2 Pump Controller – Direct On-line Starter – Quadri
The Quadri is a direct on-line starter and pump controller for use with Single and three phase systems.
It is able to control up to two pumps and balance the load between them for Boosting, Storage or Sewage pump systems.
Functions in either an automatic or manual configuration.PC3S Metal Direct On-Line Pump Controller 400VAC
A 3 Phase 400v Direct On-Line pump controller with on-demand activation from 2 inputs (float switch or pressure switch),manual override and long range remote operation options for commercial and industrial environments. Note – Many 400v controllers actually need a 230v supply as well (3P+N+PE), this controller only requires 400v (3P+PE) and can be retro-fitted where no neutral phase may be readily available.PC3S Compact Direct On-Line Pump Controller 400VAC
A 3 Phase 400v Direct On-Line pump controller with on-demand activation,manual override and long range remote operation options for commercial and industrial environments.Single/Twin Tank Level Controller
TC Series – Level based pump/valve control. Single/Twin water tank level controllerVoltage Control – 3F Control
The Mac3 3F Controls are a DIN socket mounted single phase, adjustable under-voltage monitoring and protection relays intended for use in control panels.
Mod.22 is Single Phase.
Mod.33 is three phase with additional phase loss protection.DIN Rail Mounted Level Controller – Sensopress
Mac3 Sensopress is a programmable, DIN rail mounted level controller and is ideal for integration with OEM and panel built products.
For use in Clean Water or Liquid Food Products. Mac3 Sensopress is a programmable, DIN rail mounted level controller and is ideal for integration with OEM and panel built products.
Sensopress measures the level of liquid in a tank or reservoir using a high accurate pressure sensor which detects the weight of fluid above it. Pumps and valves can be controlled to fill, empty or maintain levels by Sensopress based on the reading of a single sensor with no mechanical movement.
Sensopress avoids the need for technicians to accurately set floats or sensors at various heights within the tank in order to operate pumps and valves at the right levels. All levels and functions can be precisely set from the control panel.
Sensopress can function with any liquid using a probe and can be manually calibrated to accept probes of different ranges.
Sensopress is available in single channel and multi-channel models. The single channel model is supplied with a single output for controlling one external appliance, whereas the multi-channel is supplied with 4 outputs. Each output channel operates independently and may overlap in range.DIN Rail Mounted Pump Sequencer 3
Mac3 Sequencer is a DIN rail mounted device which balances the run-time of 2 or 3 pumps in a duty standby/assist configuration depending on model.
Pumps are alternated during normal usage, but allows the controller to activate both pumps together if there is a sudden demand.
Sequencer 3 – Advanced version of the sequencer that drives groups up to 3 pumps. Interface with LED’s and control buttons.DIN Rail Mounted Pump Sequencer 2q
Mac3 Sequencer is a DIN rail mounted device which balances the run-time of 2 or 3 pumps in a duty standby/assist configuration depending on model.
Pumps are alternated during normal usage, but allows the controller to activate both pumps together if there is a sudden demand.
Sequencer 2q – It has the same characteristics and functions as the sequencer with the addition of a panel containing two switches for pump operation and seven LED diodes that always show the system status.DIN Rail Mounted Pump Sequencer 2
Mac3 Sequencer is a DIN rail mounted device which balances the run-time of 2 or 3 pumps in a duty standby/assist configuration depending on model. Pumps are alternated during normal usage, but allows the controller to activate both pumps together if there is a sudden demand.
Sequencer 2 – Is has the same characteristics and functionality as the sequencer with the added LED’s for visualising faults.DIN Rail Mounted Pump Sequencer
Mac3 Sequencer is a DIN rail mounted device which balances the run-time of 2 or 3 pumps in a duty standby/assist configuration depending on model. Pumps are alternated during normal usage, but allows the controller to activate both pumps together if there is a sudden demand. Sequencer – In rail mounted device which balances the run-time or 2 pumps in a duty-standby/assist configuration.Pump Inverter – Swimming Pool Pumps – HydroController Pool
The HydroController Pool enables significant energy savings for swimming pool pumps by running the pump at reduced speeds when desired.
Operating parameters are customisable through the onboard interface with LCD display. Up to 4 pre-programmed speeds can be used. The advanced versions of the Controller include a WiFi feature which allows the user to configure the system from any internet location. A web-based application enables configuration of a weekly operating schedule.Pump Inverter – Off-Grid Solar Installations – HydroController Solar
A range of inverters/variable frequency drives (VFD) for use with off-grid solar power systems. The HydroController Solar adjusts the speed of the pump to match demand, and the speed is varied (if necessary) to match the available power from the solar panels.
No battery storage is required. The HydroController Solar continuously uses all the available solar energy until the required system pressure is reached.Programmable Pump Inverters – HydroController
Available in two physical configurations (Water cooled – in-line pipe mounted or Air Cooled – wall mounted) and in either Standard (controlling a single pump) or Advanced versions (multiple pumps and other features).Variable speed inverters designed for controlling water pumps in a variety of applications:
single (std) or multiple pump systems (Adv) air cooled (Wall mounted) or water cooled (in-line pipe mounted) versions for:
single phase power for a single phase pump, single phase power for three phase pump, and three phase power for three phase pumpCompact Water-cooled Inverter – E-Power
Designed for residential systems, the E-Power is ideal for Booster Pump Sets. Available in two variations, E-Power Std, and E-Power Adv.
E-Power is constructed around a stainless steel pipe and pressure sensor without non-return valve or any other flow obstruction resulting in increased system efficiency and superior reliability due to excellent self-cooling characteristics.Compact Air-Cooled Inverter – E-Power All in One
Variable speed pressure control for single or three phase pumps.
In pump mounted, the E-Power is constructed around a stainless steel pipe and pressure sensor without non-return valve or any other flow obstruction resulting in increased system efficiency and superior reliability due to excellent self-cooling characteristics.Adjustable Pressure Switch – Mechanical – MacPress
Pressure switch for single and three phase pump contol in boosting systems with a pressure vessel.Pump Pressure Switch – Adjustable Pressure – PresSystem
Single phase pump controller which is installed on clean-water pipe work. By using a single speed, variable pressure control system, the PresSystem ensures pump efficiency by reducing the time a pump is run to maintain pressure in the system. Dry Run Protection via either a Float Switch (not included) or built in CosPhi option.Home Boosting – Electronic Pump Pressure Controller – E-Control
For home (domestic) header tank boosting or in-line boosting of low mains water pressure. Pump control for pressure boosting by pressure and flow detection. The pump starts by pressure/flow sensing and the pump is stopped by flow sensing. When either water flow or a pressure drop is detected, the E-Control engages the pump to maintain pressure in the system until it detects that the flow has stopped when it disengages the pump. Clean water only.Home Boosting – Electronic Flow Switch – E-Flow
For home (domestic) header tank boosting or in-line boosting of low mains water pressure. Pump control for pressure boosting by flow detection. When a flow is detected in the pipe, E-Flow runs the pump to increase pressure in the system until it detects that the flow has stopped. E-Flow can control a single phase pump of up to 2 Hp (1.5kW). Clean water only.Electronic Pump Controller – SuperSimplex E
Pump pressure with built in dry run protection. A warning light on the control panel indicates if there is a fault. Controls single phase clean water pumps up to 2Hp (1.5kW).
This model uses pressure and flow sensing to decide when to run the pump.Electromechanical Pump Controller – SuperSimplex M
Pump pressure switch for use with a float switch for dry run protection. Controls single phase clean water pumps up to 2Hp (1.5kW).Inverter with External Sensors: Single / Three Phase 230V and 400V
INV Series Highly versatile variable frequency drives designed to control and protect commercial plumbing systems by varying or changing pump speed.For more information Contact us
Self Contained, Pump Outlet Mounted Inverter: Single / Three Phase 230V
XINV Series Adjusts pump motor speed to maintain constant pressure. The desired pressure can then be adjusted from the keypad.For more information Contact us
Multiple Booster Pump Controller
PF Series – Pressure based pump control (variable pressure). Multiple booster pump controller. Pressure control of multiple pumps from a single Control Panel and pressure sensor. Fixed speed variable pressure pump control with adjustable start and stop pressures per pump, and intuitive menu driven options.